Safety
Leuze electronic MLC 510 7
2 Safety
Before using the safety sensor, a risk assessment must be performed according to valid standards (e.g.
ENISO12100:2010, ENISO13849‑1:2015, EN62061:2005+A1:2012). The result of the risk assessment
determines the required safety level of the safety sensor (see chapter 14.1 "Safety-relevant technical
data").
For mounting, operating and testing, this document as well as all applicable national and international stan-
dards, regulations, rules and directives must be observed. Relevant and supplied documents must be ob-
served, printed out and handed to affected persons.
Ä Before working with the safety sensor, completely read and observe the documents applicable to your
task.
In particular, the following national and international legal regulations apply for the commissioning, techni-
cal inspections and work with safety sensors:
Directive 2006/42/EC
Directive 2014/35/EU
Directive 2014/30/EU
Directive 89/655/EEC supplemented by directive 95/63EC
OSHA 1910 Subpart O
Safety regulations
Accident-prevention regulations and safety rules
Ordinance on Industrial Safety and Health and employment protection act
Product Safety Law (ProdSG and 9. ProdSV)
NOTICE
For safety-related information you may also contact local authorities (e.g., industrial inspec-
torate, employer's liability insurance association, labor inspectorate, occupational safety and
health authority).
2.1 Intended use and foreseeable misuse
WARNING
A running machine may result in serious injury!
Ä Make certain that the safety sensor is correctly connected and that the protective function of
the protective device is ensured.
Ä Make certain that, during all conversions, maintenance work and inspections, the system is
securely shut down and protected against being restarted.
2.1.1
Intended use
The safety sensor may only be used after it has been selected in accordance with the respectively ap-
plicable instructions and relevant standards, rules and regulations regarding labor protection and safety
at work, and after it has been installed on the machine, connected, commissioned, and checked by a
competent person (see chapter 2.2 "Necessary competencies"). The devices are designed for indoor
use only.
When selecting the safety sensor it must be ensured that its safety-related capability meets or exceeds
the required performance level PL
r
ascertained in the risk assessment (see chapter 14.1 "General
specifications").
The safety sensor protects persons or body parts at points of operation, danger zones or access points
of machines and systems.

Table of Contents

Other manuals for Leuze electronic MLC 520 EX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leuze electronic MLC 520 EX Series and is the answer not in the manual?

Leuze electronic MLC 520 EX Series Specifications

General IconGeneral
BrandLeuze electronic
ModelMLC 520 EX Series
CategoryLighting Equipment
LanguageEnglish

Related product manuals