EasyManua.ls Logo

Leviton 7000 Series - User Manual

Leviton 7000 Series
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Advanced Multi-Circuit Meter 7000/7100 Series
User's Guide
Cat. Nos. 71D12, 71D48, 70D12, 70D48, 70N12, 70N48,
71D24, 70D24, 70N24, 71D03, 70D03
PK-A3259-10-00-0D
Cat. 71D24 and 71D48Cat. 71D12
Cat. 70D48
Cat. 70D12
VerifEye
®
Cat. 71D03
Cat. 70D03
Cat. 70D24
WEB VERSION
Question and Answer IconNeed help?

Do you have a question about the Leviton 7000 Series and is the answer not in the manual?

Summary

Warnings and Cautions

Introduction to VerifEye Meters

Unpacking the Unit

Details on how to unpack the VerifEye meter and its included accessories.

Meter Anatomy

Identifies and describes the various connectors and components on the meter's circuit board.

Planning for Field Installation

Project Manager Aspects

Guidance for project managers on coordinating installation tasks and required tools.

Meter Configuration Overview

Outlines the steps and tools for configuring the meter before installation.

Meter Installation Overview

Summarizes the tasks performed by a licensed electrician for meter installation.

Verification and Communication Overview

Describes the process of verifying meter operation and communication setup.

RTU Programming and Scripting Overview

Provides an overview of tools and tasks for RTU programming and scripting.

Meter Configuration

Install Power Meter Viewer Utilities Software

Step-by-step guide for installing the necessary software for meter configuration.

Connectivity Options

Details on connecting the meter via USB, Ethernet, and direct connections.

Advanced Configuration Tools

Using Network Scan and Launch Configurator for meter setup and management.

Configuration Procedures

Steps for configuring electrical components, RS-485, and Ethernet communications.

Configuring Alarms

Instructions on setting up over/under voltage and current alarms using the software.

Data Logging and Time Settings

Procedure for setting the meter's real-time clock and retrieving interval data.

VerifEye Web App Overview

Introduction to accessing meter data and configuration via a web browser on smart devices.

Meter Installation

Meter Mounting Configurations

Describes different mounting options for VerifEye® meters, including enclosure and panel mount.

Installation Sequence

Step-by-step guide for installing the enclosure models of the meter.

Installation Sequence for 70 D03 Model

Specific installation steps for the 70D03 model using DIN rail mounting.

Wiring in a 3-Wire, Split-Phase Service Panel

Detailed wiring instructions for split-phase service panel installations.

Wiring in a 3 Phase, 4-Wire Service Panel

Detailed wiring instructions for 3-phase, 4-wire WYE service panel installations.

Current Transformers Basics

Guidelines for selecting, orienting, and connecting current transformers (CTs).

Wiring the CTs to the Meter

Diagrams and instructions for connecting CTs to meter input terminals for various service types.

Communication and Verification

RS-485 Network Connections

Explains physical connection requirements and components for RS-485 networks.

Verification Procedures

Steps to verify communication settings, interface, and protocols using LCD or software.

Modbus Settings

Configuration details for Modbus RTU and Modbus TCP protocols.

BACnet Settings

Configuration details for BACnet MS/TP and BACnet IP protocols.

Alarms (SPDT)

Details on configuring user-programmable alarms for voltage and current conditions.

Security PIN Protection

Explains the two levels of PIN protection for restricting access to meter information.

Installation Verification Checks

Procedures for verifying CT installation and phase association using PhaseChek and Phasor Plot.

Power Factor and Harmonic Analysis

Explains power factor conventions and analysis of total harmonic distortion (THD).

RTU Programming and Scripting

Register and Scope Definitions

Defines the structure of meter registers and the scope of elements and systems.

Configuring Registers for Service Types

Tables detailing register settings for various electrical service types.

System Registers and Modbus Commands

How to configure system registers and lists supported Modbus commands.

Floating Point Registry Entry

How to handle and enter 32-bit IEEE 754 floating point numbers for meter registers.

Processor Reset Commands

Instructions on how to perform a soft reset of the VerifEye® meter.

BACnet Protocol Details

Information on BACnet protocol, device IDs, and structured view objects.

Appendix A: LCD Menu Navigation

About Meter Menu Navigation

Details on accessing and navigating the "About Meter" menu on the LCD display.

Appendix B: Technical Specifications

Main Meter Specifications

Lists key electrical and measurement specifications for the VerifEye® meters.

Communication Specifications

Details hardware, protocols, and communication interface specifications.

Mechanical Specifications

Provides physical dimensions, mounting, and environmental specifications for the meters.

Standard Statements and Warranty

Limited 5 Year Warranty

Outlines the terms, conditions, and exclusions of the product's limited warranty.

Summary

Warnings and Cautions

Introduction to VerifEye Meters

Unpacking the Unit

Details on how to unpack the VerifEye meter and its included accessories.

Meter Anatomy

Identifies and describes the various connectors and components on the meter's circuit board.

Planning for Field Installation

Project Manager Aspects

Guidance for project managers on coordinating installation tasks and required tools.

Meter Configuration Overview

Outlines the steps and tools for configuring the meter before installation.

Meter Installation Overview

Summarizes the tasks performed by a licensed electrician for meter installation.

Verification and Communication Overview

Describes the process of verifying meter operation and communication setup.

RTU Programming and Scripting Overview

Provides an overview of tools and tasks for RTU programming and scripting.

Meter Configuration

Install Power Meter Viewer Utilities Software

Step-by-step guide for installing the necessary software for meter configuration.

Connectivity Options

Details on connecting the meter via USB, Ethernet, and direct connections.

Advanced Configuration Tools

Using Network Scan and Launch Configurator for meter setup and management.

Configuration Procedures

Steps for configuring electrical components, RS-485, and Ethernet communications.

Configuring Alarms

Instructions on setting up over/under voltage and current alarms using the software.

Data Logging and Time Settings

Procedure for setting the meter's real-time clock and retrieving interval data.

VerifEye Web App Overview

Introduction to accessing meter data and configuration via a web browser on smart devices.

Meter Installation

Meter Mounting Configurations

Describes different mounting options for VerifEye® meters, including enclosure and panel mount.

Installation Sequence

Step-by-step guide for installing the enclosure models of the meter.

Installation Sequence for 70 D03 Model

Specific installation steps for the 70D03 model using DIN rail mounting.

Wiring in a 3-Wire, Split-Phase Service Panel

Detailed wiring instructions for split-phase service panel installations.

Wiring in a 3 Phase, 4-Wire Service Panel

Detailed wiring instructions for 3-phase, 4-wire WYE service panel installations.

Current Transformers Basics

Guidelines for selecting, orienting, and connecting current transformers (CTs).

Wiring the CTs to the Meter

Diagrams and instructions for connecting CTs to meter input terminals for various service types.

Communication and Verification

RS-485 Network Connections

Explains physical connection requirements and components for RS-485 networks.

Verification Procedures

Steps to verify communication settings, interface, and protocols using LCD or software.

Modbus Settings

Configuration details for Modbus RTU and Modbus TCP protocols.

BACnet Settings

Configuration details for BACnet MS/TP and BACnet IP protocols.

Alarms (SPDT)

Details on configuring user-programmable alarms for voltage and current conditions.

Security PIN Protection

Explains the two levels of PIN protection for restricting access to meter information.

Installation Verification Checks

Procedures for verifying CT installation and phase association using PhaseChek and Phasor Plot.

Power Factor and Harmonic Analysis

Explains power factor conventions and analysis of total harmonic distortion (THD).

RTU Programming and Scripting

Register and Scope Definitions

Defines the structure of meter registers and the scope of elements and systems.

Configuring Registers for Service Types

Tables detailing register settings for various electrical service types.

System Registers and Modbus Commands

How to configure system registers and lists supported Modbus commands.

Floating Point Registry Entry

How to handle and enter 32-bit IEEE 754 floating point numbers for meter registers.

Processor Reset Commands

Instructions on how to perform a soft reset of the VerifEye® meter.

BACnet Protocol Details

Information on BACnet protocol, device IDs, and structured view objects.

Appendix A: LCD Menu Navigation

About Meter Menu Navigation

Details on accessing and navigating the "About Meter" menu on the LCD display.

Appendix B: Technical Specifications

Main Meter Specifications

Lists key electrical and measurement specifications for the VerifEye® meters.

Communication Specifications

Details hardware, protocols, and communication interface specifications.

Mechanical Specifications

Provides physical dimensions, mounting, and environmental specifications for the meters.

Standard Statements and Warranty

Limited 5 Year Warranty

Outlines the terms, conditions, and exclusions of the product's limited warranty.

Leviton 7000 Series Specifications

General IconGeneral
BrandLeviton
Model7000 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals