6 STATUS LIGHT KEY
9
6.1 Status Description of the Charger Indication Light
WARNINGS:
• Be sure to preview the user manual and ensure local building and electrical codes are reviewed before
installing the AC charger.
• The AC charger should be installed by a qualied technician according to the user manual and local
safety regulations.
• Use appropriate protection when connecting to the main power distribution cable.
• Type B, C or D breaker with the rating current for table should be installed in the upstream AC
distribution box.
• Disconnect switch for each ungrounded conductor of AC input shall be provided by
others in accordance with the National Electrical Code, ANSI/NFPA 70.
Status of Charger Indication Light
Standby - Blue Light
The READY light stays steady in standby mode.
Waiting for Charge - Green Light
After the vehicle connector is connected
to the vehicle inlet, the CHARGE light is
constantly lit.
Charging - Green Light Flashing
The CHARGE light ashes while charging
Fault - Red Light
The red light is lit while fault. Please refer
to section 9 “Error and Warning Messages”
for detailed information.
MyLeviton Setup Mode - Blue Light Flashing
(EV32W, EV48W, EV80W and EV40P only)
Blue Light
Green Light
Red Light
Green Light
Flashing
Blue Light
Flashing