26 58D6056
CHECKING GAS PRES SURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install
the appliance. Contact your dealer immediately.
2. To ease installation, a 30" (mm) flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach
1
/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a soap and water solution
or a gas sniffer.
4. To adjust flame height, turn HI/LO knob to HI to get
maximum pressure to burner. Turn HI/LO knob to LO
to get minimum pressure.
5. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
See Figure 33. After taking pressure reading, be sure
and turn captured screw clockwise firmly to reseal. Do
not over torque. Check test points for gas leaks with a
soap and water solution.
Do not use open fl ame to check for
gas leaks.
WARNING
Figure 33 - Gas Pressure Check at Gas Valve
Pressure
Test “IN”
Pressure
Test “OUT”
HI/LO
Knob
Pilot Adjustment
Screw