EasyManua.ls Logo

LG APUW100LFT0 - Connecting Cables between Indoor Unit and Outdoor Unit

LG APUW100LFT0
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WIRING CONNECTION
13
ENGLISH
Connecting cables between indoor unit and outdoor unit
Outdoor
unit
Indoor
unit
1
2
3
1
2
3
The power cable connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4
(This equipment shall be provided with a cable set complying with the national regulation.
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cable set complying with the national
regulation.)
If the supply cable is damaged, it must be replaced by a special cable or assembly availible
from the manufacturer of its service agent.
When the connection line between the indoor unit and out-
dooor unit is over 40 m, connect the telecommunication
line and power line separately.
CAUTION
!
NORMAL
CROSS-SECTIONAL
AREA 1.5 mm
2
20
mm
G
N/YL
35±5 mm
10±3 mm
Model Phase(Ø) Area(mm
2
) Cable Type
APUQ100LFT0
APUW100LFT0
3 6.0 H07RN-F
20
m
m
G
N/Y
L
35±5 mm
10±3 mm
For the 3-Phase

Related product manuals