EasyManua.ls Logo

LG APUW100LFT0 - Self-Diagnosis Function; Error Indicator (Outdoor)

LG APUW100LFT0
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
SELF-DIAGNOSIS FUNCTION
ENGLISH
Error indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
1 Time 1 Time 1 Time
2 Times2 Times2 Times
1 Sec.
2 Sec. 2 Sec.
1 Sec. 1 Sec.
LED01G
(RED)
LED02G
(GREEN)
SELF-DIAGNOSIS FUNCTION
Error Indicator
- The function is to self-diagnosis air conditioner and express the troubles identically if there is
any trouble.
- Error mark is ON/OFF for the operation LED of display parts in the same manner as the follow-
ing table.
- If more than two troubles occur simultaneously, primarily the highest trouble of error code is ex-
pressed.
- After error occurrence, if error is released, error LED is also released simultaneously.
- To operate again on the occurrence of error code, be sure to turn off the power and then turn
on.
- Having or not of error code is different from model.
Model
PCB
APUW100LFT0
APUQ100LFT0
Main
Inverter