24
OPTIONAL OPERATION
ENGLISH
Installer Setting - Setting Address of Central Control
It's the function to use for connecting central control.
Please refer to central controller manual for the details
Set Group No. by pressing         
button.(0~F)
3
Move to Indoor No. setting option 
by pressing       button.
4
Set Indoor No. by pressing 
 button.
5
Press        button to save.
6
Pressing        button will exit settings mode.
❈ After setup, it automatically gets out of setup 
mode if there is no button input for 25 
seconds.
❈ When exiting without pressing set button, the 
manipulated value is not reflected.
7
If entering into address setup mode by using      
       button, it indicates as picture below.
2
If pressing   button long for 3 
seconds, it enters into remote controller 
setter setup mode.
- If pressing once shortly, it enters into 
user setup mode. Please press more 
than 3 seconds for sure.
1
Function Code
Group No
Indoor No.
1,MFL67939930,영영  2018. 3. 16.  영영 2:25  Page 24