OPTIONAL OPERATION
ENGLISH
31
Installer Setting - Remote controller Mode Lock
This function is used to limit ‘operation-mode’ selection setting.
code Description
42:00
42:01
42:02
Doesn’t limit operation mode setting.
User can setting to cooling mode only.
User can setting to heating mode only.
Press and hold         button for 
more than 3 seconds to enter the 
installer settings mode.
1
Press        button to exit.
5
Move to the installer code number 42 in the 
menu using        button.
2
Select the remote control master/slave 
using       button.
3
Press        button to save the setting.
4
Code value for mode
lock setting
Set value
h It can limit only wired remote controller button. other controllers can change operation mode. 
(for example wireless remote controller and central controller) 
1,MFL67939930,영영  2018. 3. 16.  영영 2:25  Page 31