5. Trouble Shooting
6.18 Check code Trouble shooting CH40
V
Check the input power
AC230V
(Outdoor, Indoor unit)
Is it normal ?
( 230V±10%)
Change main PCB
Check C01N
Is it normal (4.0Vdc )?
Check Check TRANS
Is it normal?
Yes
Yes
Yes
No
Correct connection
No
Change Main PCB
No
Change TRANS
Check Flow Chart
TRANS
C01N
40
C/T
Internal circuit
Initial current error
Malfunction of current detection circuit.
(Open / Short)
The voltage of C01N Is 4.0Vdc (25A) .
Display
code
Title Cause of error Check point & Normal condition