Installation
Installation Manual 25
ENGLISH
Terminal block 2
Terminal block 1
Connection for thermostat
(230V~)
Supporting type : Heating only
THERMOSTAT
(Default : 230V AC)
11
L
BR
12
N
BL
13
L1
BR
14
L2
BK
energizing water
pump for solar
thermal system
water flow switching between
under floor heating and sanitary
water tank heating
water flow switching between using
solar thermal heating and skipping
solar thermal heating
turn on or off sanitary
water tank heater
3WAY VALVE
(B)
WATER
PUMP
(B)
WATER
TANK
HEATER
3WAY VALVE
(A)
1
L
BR BK BL BR BL BR BR BKBL BL
2
L1
3
N
4
L
5
N
6
L
7
N
8
L
9
L1
10
N
Terminal block information
Symbols used below pictures are as follows :
- L, L1, L2 : Live (220-240 V~ 50 Hz)
- N : Neutral (220-240 V~ 50 Hz)
- BR : Brown , WH : White , BL : Blue , BK : Black, GR/YL : Green/Yellow
The power cord connected to the unit should be selected according to the following
specifications.
CAUTION

Other manuals for LG Therma V AHBW A0 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG Therma V AHBW A0 Series and is the answer not in the manual?

LG Therma V AHBW A0 Series Specifications

General IconGeneral
BrandLG
ModelTherma V AHBW A0 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals