Chapter 1 Preliminary Operations 1
Liebert.CRV Series Air Conditioner User Manual
Chapter 1 Preliminary Operations
This chapter introduces the preliminary operations of the Liebert.CRV series air conditioner (Liebert.CRV for short),
including inspection, handling, operating limits, noise level limits and product description.
Warning
- Risk of top-heavy unit falling over
Risk of top-heavy unit falling over. Can cause death, injury and equipment damage. Read all of the following instructions before
attempting to move, lift or remove packaging from the unit.
Caution
- Risk of sharp edges, splinters and exposed fasteners
Risk of sharp edges, splinters and exposed fasteners. Can cause personal injury. Only trained personnel wearing appropriate
safety headgear, gloves, shoes and glasses should attempt to move, lift or remove packaging from the unit or prepare the unit for
installation.
Caution
- Risk of overhead interference
Risk of overhead interference. Can damage the unit and structure. The unit may be too tall to fit through a doorway while on the
skid. Measure the unit and doorway heights and refer to the installation plans to verify clearances before moving the unit.
Caution
- Risk of frozen fluids
Risk of frozen fluids. Can cause equipment damage. Keep the unit upright, indoors and protected from dampness, freezing
temperatures and contact damage.
1.1 Inspection
Upon arrival of the unit, and before unpacking it, verify that the delivered equipment matches the bill of lading.
Examine the packaging for any signs of mishandling or damage. Inspect all items for damage, visible or concealed.
Report any damage immediately to the carrier and file a damage claim. Send a copy to Emerson Corporation or to
your sales representative.
1.2 Handling
Always keep the unit vertically upright and do not leave it out in the open.
If possible, transport the Liebert.CRV using a forklift or pallet jack. Otherwise use a crane with belts or cables
and spreader bars to protect the unit’s sides from damage.
If using a forklift or pallet jack, make sure the forks (if adjustable) are spread to the widest distance that fit under
the skid. Also, ensure the fork length is suitable for the unit length.
When moving the packaged unit, do not lift it any higher than 152 mm off the ground. Exercise great care if the
unit must be lifted higher than 152 mm; any personnel not directly involved in lifting the unit must be at least 5m
from the unit.
Take care of the Center of Gravity indicated on the package.