Troubleshooting
Symptom Possible cause Remedy
Battery icon is displayed Batteries are low Replace batteries
Display blank Meter asleep. Push reset button.
Loose battery connection. Remove battery pack and check battery connection and push
reset button
Batteries dead. Replace batteries and push reset button
Program error Remove and reinsert battery pack. Push reset button.
Meter does not latch for batching Meter not in auto mode. Press auto button and program batch size
Meter not reset after prior batch. Press reset button
Low batteries. Check for battery icon, replace batteries and push reset button.
Slow or no fluid flow Filter is clogged. Clean or replace the filter in the swivel nut.
Pump pressure is low. Turn up the pump pressure.
Foreign material is jamming meter. Contact your local distributor for repair.
Meter inaccurate Scale factor not correct for fluid Enter program mode, check and reset program factor
Relieve the pressure prior to
checking or repairing the meter.
Make sure all valves, controls and
pumps are operating correctly.
Failure to comply may result in
serious injury or death.