Rev: 06.14.24 Page 10 CCD-0007721
Operating Modes
Presses Function Description
7 – hold on the seventh press Enter Electronic Override Mode Enter Electronic Override Mode
1 – hold on first press
Return to normal operating
mode
Returns the controller to normal
operating mode
Switching Between Operating Modes
It is possible to switch between operating modes using the mode button. The controller will return to
normal operating mode on its own after 2 minutes, even if being driven.
NOTE: When in electronic override mode, electronic protections will be disabled.
Factory Resetting and Initial Synchronization
After maintenance and during troubleshooting, a factory reset (See Performing A Factory Reset section) may
need to be performed, After performing a factory reset, perform an initial synchronization to ensure the sides of
the slide-out are properly aligned.
When to Perform a Factory Reset
After swapping motors.
After reversing a motor’s polarity to correct slide travel direction.
After repairing faulty motor harnesses.
After swapping controllers to operate different slides – even known good motors. Each slide is unique.
During the initial installation of a controller on a slide fresh from factory.
Performing A Factory Reset
A factory reset will clear current synchronization. To perform a factory reset, press the mode button 5 times
and hold on the 5th press for at least 1 second.
NOTE: After performing a factory reset, users will need to follow the steps under the initial synchronization
instructions. Otherwise, the slide will not synchronize properly and may be misaligned or jackknife.
Performing an Initial Synchronization
1. Retract slide-out until controller shuts motors off.
2. Confirm slide-out is fully retracted and controller does not report any faults.
3. Extend slide-out until controller shuts motors off.
4. Confirm slide-out is fully extended and controller does not report any faults.
5. Retract slide-out until controller shuts motors off.
6. Confirm slide-out is fully retracted and controller does not report any faults.