Rev: 06.14.24 Page 6 CCD-0007721
Manual Override Mode
In the event that power is lost to the slide-out motor(s), the slide-out room can be manually retracted by
following these steps.
1. Gain access from inside the unit to the vertical channel assembly by removing the OEM trim and flange
pieces on the slide-out room box. The motors are located at the top of the channel.
2. If applicable, use a Phillips head screwdriver to remove the top screw from the bulb seal at the top of
the vertical channel (Fig. 2).
3. Pull down the bulb seal and remove the motor cover (Fig. 3). The motor cover may stick to the bulb
seal.
4. Using a
⁄"
open-ended wrench or ratcheting box wrench, loosen the motor retaining screw from the
block by turning
½
-
¾
turn, (Fig. 4). Do not remove the motor retaining screw.
5. Remove the motor by lifting it up and out of the column.
6. Repeat steps 1-6 for the other side.
7. Push the slide-out room uniformly into the retracted position.
8. Once the slide-out room is retracted, secure the slide-out room in place by:
A. Re-installing the motors.
NOTE: Make sure the motor is properly seated on the block with no gap between the mounting bracket
and block.
B. Tighten the motor retaining screw (Fig. 4) with the motor retainer fully engaged.
C. Using a transit bar (slide-out locking bar).
9. Have the slide-out room serviced by the OEM-authorized dealer as soon as possible. Do not operate
slide-out room until service is complete, as damage to the slide-out room may result.
Fig. 2
Fig. 3
Retaining
Screw
Fig. 4
When manually retracting the slide-out room, make sure that both sides of the slide-out room move
together. Damage to the slide-out room may result if movement is not uniform.