Rev: 06.14.24 Page 13 CCD-0007721
Basic Fault Reporting Mode Table
Green LED
Red
LED
DTC: Diagnostic
Trouble Code
Description Troubleshooting Steps
1 (Basic fault) 1 Left motor fault
There is a problem
with the left
motor circuit.
Check connections on the motor,
the controller and check the wire
harness for damage. Motor may
need to be replaced.
1 (Basic fault) 2 Right motor fault
There is a problem
with the right
motor circuit.
Check connections on the motor,
the controller and check the wire
harness for damage. Motor may
need to be replaced.
1 (Basic fault) 3 Battery fault
There is a problem
with the detected
battery power.
Ensure the battery is fully charged
and try actuating again.
1 (Basic fault) 4 Parking brake fault
There is a problem
with the parking
brake signal.
Check to ensure the parking brake
is engaged.
1 (Basic fault) 5 Switch power fault
There is a problem
with the switch
circuit.
Check connections on the switch,
the controller and check the wire
harness for damage. Switch may
need to be replaced.
Maintenance
The Lippert slide-out system has been designed to require very little maintenance. To ensure the long life of the
slide-out system, follow these simple procedures:
1. When slide-out room is extended, visually inspect the slide gear rack assemblies. Check for excess
buildup of dirt or other foreign material. Remove any debris that may be present.
2. If the system squeaks or makes any noises, hand apply a dry lubricant to prevent and/or stop
squeaking.