Rev: 06.14.24 Page 7 CCD-0007721
A
Fig. 5
Alternate Override Modes
If none of the previous override methods retract the slide-out room, it may be possible to manually retract
the slide-out room by one of the following alternate methods. Both of these procedures will only be possible
if there is access to the described areas.
1. Manually retract the slide-out room using a ratchet and socket attached to the end of the coupler
(Fig. 5A) to move the slide-out room.
A. Remove the motor. Follow steps 1-6 under the Manual Override Mode section.
B. Place a ratcheting wrench with a 3” extension and
⁄”
deep well socket through the motor access
opening and seat the socket onto the coupler (Fig. 5A).
C. Using the ratcheting wrench with socket and alternating from one side to the other, turn the
wrench to bring the slide-out room in.
NOTE: One person per side of the slide-out room (two total) with ratchet and socket will expedite the
process. Make sure that both sides of the slide-out room retract together uniformly. The slide-out
room moves approximately
¼”
for every 30-40 degree turn of the wrench.
D. Once the slide-out room is retracted, secure the slide-out room in place by:
I. Re-installing the motors.
NOTE: Make sure the motor is properly seated on the block with no gap between the mounting bracket
and block.
II. Tighten the motor retaining screw (Fig. 4) with the motor retainer fully engaged.
III. Using a transit bar (slide-out locking bar).
E. Have the slide-out room serviced by an OEM-authorized dealer as soon as possible. Do not
operate the slide-out room until service is complete as damage to the slide-out room may result.