Rev: 06.14.24 Page 8 CCD-0007721
Gear
Rack
Drive Shaft
Spur Gear
Fig. 6
2. Manually retract the slide-out room by turning the
½”
square drive shaft of each vertical channel
assembly.
A. Remove the motor. Follow steps 1-6 of the Manual Override Mode.
B. Access the
½"
square drive shaft (Fig. 6) of each vertical channel.
C. Using a
½”
8-point star socket and alternating from one side to the other, turn the
½”
square
drive shaft to bring the slide-out room in. A 15 mm 12-point socket is an option if the
½”
8-point
star socket is not available. Use caution, as the 15 mm 12-point socket does not fit as snug as the
½”
8-point socket.
D. Once the slide-out room is retracted, secure the slide-out room in place by:
I. Re-installing the motors.
NOTE: Make sure the motor is properly seated on the block with no gap between the mounting bracket
and block.
II. Torquing the motor retaining screw to 40 in lbs. (Fig. 4) with the motor retainer fully engaged.
III. Using a transit bar (slide-out locking bar).
E. Have the slide-out room serviced by the OEM-authorized dealer as soon as possible. Do not
operate slide-out room until service is complete as damage to the slide-out room may result.
When manually retracting the slide-out room, make sure that both sides of the slide-out room move
together. Damage to the slide-out room may result if movement is not uniform.