Rev: 06.14.24 Page 12 CCD-0007721
LED Indications
• When driving motors, the green LED and red LED will blink synchronously.
• When indicating faults, the LEDs blink sequentially, report all faults and repeat. The green LED will blink
once or twice to indicate the reporting mode, followed by one to several blinks of the red LED to indicate
each fault.
Examples
A right motor fault:
Green LED blinks once, followed by the red LED blinking twice, then repeating. Then both lights will blink at
the same time to indicate the beginning of the sequence and the pattern repeats.
A left motor fault and a right motor fault:
Green LED blinks once, red LED blinks once, green LED blinks once, red LED blinks twice. Then both lights
will blink at the same time to indicate the beginning of the sequence and the pattern repeats.
• When switching between modes, both LEDs will blink to acknowledge the user selection.
Factory reset:
After pressing the mode button 5 times to initiate a factory reset, there will be 5 blinks.
Electronic override mode:
When in electronic override mode, the LEDs will rapidly blink one after another while the mode is active.
Active fault warnings and other electronic protections will be disabled.