Sets the frequency to b6-00 used to be held
for the time set in b6-01 during acceleration.
Default
∶
0.0 Hz
Min.: 0.0 Hz
Max.: <5>
Default
∶
0.0 s
Min.: 0.0 s
Max.: 10.0 s
Sets the frequency to b6-02 used to be held
for the time set in b6-03 during deceleration.
Default
∶
0.0Hz
Min.: 0.0 Hz
Max.: <5>
Default
∶
0.0 s
Min.: 0.0 s
Max.: 10.0 s
b9 : Position Control / Zero Speed Holding
Zero Speed
Holding On/ Off
0 :Zero Speed Holding Disabled.
Drive coasts to stop when the frequency is zero.
1 : Zero Speed Holding Enabled.
Zero Speed Holding starts when the
frequency is zero. The holding current is set in
b2-01 and it will be limited to below 20% of
the drive rated current.
Default
∶
0
Min.: 0
Max.: 1
Sets the Zero Speed Holding time. Drive will
coast to stop when the Zero Speed Holding
time is longer than this setting. Set 00.00 to
disable Zero Speed Holding or set 99.99 to
enable this function continuesely .
Default
∶
0.10sec
Min.: 00.00sec
Max.: 99.99sec
Sets the time that the drive accelerates from
0Hz to the maximum output.
Default: depends on
the HP
10HP and below: 10s
15HP and 20HP: 15s
25HP and above: 20s
Min.: 0.0 s
Max.: 6000.0 s
Sets the time that the drive decelerates from
the maximum output to 0Hz.
Sets the time that the drive accelerates from
0Hz to the maximum output.
Sets the time that the drive decelerates from
the maximum output to 0Hz.
Sets the time that the drive accelerates from