47
4.3.3 Control Circuit Cable Size and Tightening Torque
Select the cable according to Table 4.3.3.1. Use crimp ferrules on the cable ends for simpler and
more reliable wiring.
Table 4.3.3.1 Cable Size and Tightening Torque
Tightening
Torque
Nm
( lb.in.)
Applicable Size
mm2
( AWG)
Suggested Size
mm2
( AWG)
Applicable Size
mm2
( AWG)
Suggested Size
mm2
( AWG)
V-,24V,S1,S2,S3,S4,S5,S6
,S7,S8,DC,D1,D2
V+,COM,A1,A2,FM,AM,A
C,MT,RP,PC,MP,PC,PE
4.3.4 Ferrule-Type Terminals
Always use ferrule-type terminals with insulated sleeves. Refer to Table 4.3.3.2. for dimensions. In
addition, crimping tool CRIMPFOX ZA-3 manufactured by Phoenix Contact is recommended.