0 : Open-Loop V/F Control
This method is recommended for those applications without the need of fast response,
accurate speed control. Select this method also when using a single drive to run more than
one motors, the motor parameters are unknown or Auto-Tuning cannot be performed. The
speed control range is 1 : 40.
1 : Sensorlees Voltage Vector Control (SVVC, Open-Loop)
This method is recommended for those applications which high torque at low speed and quick
torque response without any speed feedback signal from the motor during speed adjustment.
The speed control range is 1 : 100.
A1-03 Reset
Resets parameter settings to default settings. After resetting parameters, the value will
automatically set to 0.
No.
Name
Setting Range
Default
A1-03
Reset
0 to 3646
o2-03
0: N/A
2520: Resets 2-Wire Sequence / 50Hz / 200V
2522: Resets 2-Wire Sequence / 50Hz / 220V
2523: Resets 2-Wire Sequence / 50Hz / 230V
2620: Resets 2-Wire Sequence / 60Hz / 200V
2622: Resets 2-Wire Sequence / 60Hz / 220V
2623: Resets 2-Wire Sequence / 60Hz / 230V
3520: Resets 3-Wire Sequence / 50Hz / 200V
3522: Resets 3-Wire Sequence / 50Hz / 220V
3523: Resets 3-Wire Sequence / 50Hz / 230V
3620: Resets 3-Wire Sequence / 60Hz / 200V
3622: Resets 3-Wire Sequence / 60Hz / 220V
3623: Resets 3-Wire Sequence / 60Hz / 230V
2538: Resets 2-Wire Sequence/ 50Hz / 380V

Table of Contents

Other manuals for LiteOn EVO600043S2D2E20F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LiteOn EVO600043S2D2E20F and is the answer not in the manual?

LiteOn EVO600043S2D2E20F Specifications

General IconGeneral
BrandLiteOn
ModelEVO600043S2D2E20F
CategoryController
LanguageEnglish

Related product manuals