Three Phase 400V Class
Model
Rated Current (A)
2kHz
8kHz
10kHz
12kHz
440V 0.5HP (0.4kW)
1.5
1.5
13.5
14
440V 1HP (0.75kW)
2.5
2.5
2.2
2
440V 2HP (1.5kW)
4.2
4.2
3.8
3.4
C7-00 SVVC Porortional Gain
According to application feature to set this gain, if the load is heavy increase the value, and
vice versa to reduce this value. Recommend to adjust 10% roughly and then adjust 1% minute.
No.
Name
Setting Range
Default
C7-00
Proportional Gain
0 to 100%
30%
6.4 Group L, Frequency Command
L1 Frequency Command
b1-00
Frequency Command
Source 1
RS-485 Commnunication
External I/O Terminal
Terminal A1
L01-00
Frequency Command
b1-07
Frequency Command
Source 2
RS-485 Commnunication
External I/O Terminal
Terminal A1
L01-00
Frequency Command
L1-01
L1-02
L1-03
L1-14
L1-15
L1-16
Frequency
Command
= 3
= 2
= 1
= 0
= 3
= 2
= 1
= 0
Multi-Function
Input
E1-00 = 4
0
1
Remote
Local
Multi-Step Speed
1
Frequency
Command
4~16
Job
Command
Multi Step
Speed 2
Multi Step
Speed 3
1Multi Step
Speed 4
1Multi Step
Speed 15
Multi-Step
Speed 16
Jog Command
Multi-Step Speed
Command
307E3
Open
Closed
E1-□□= 9
Figure 6.34 Frequency Command Diagram

Table of Contents

Other manuals for LiteOn EVO600043S2D2E20F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LiteOn EVO600043S2D2E20F and is the answer not in the manual?

LiteOn EVO600043S2D2E20F Specifications

General IconGeneral
BrandLiteOn
ModelEVO600043S2D2E20F
CategoryController
LanguageEnglish

Related product manuals