LXC706 Series Genset Controller
Dongguan Tuancheng Automation Equipment Co.,Ltd.
LXC706 Product User Manual Dongguan Tuancheng Automation Equipment Co.,Ltd.
: +86-769-23836636 : F:+86-769-23166296 : www.lixise.com
Page
4
of
17
With 3 working state: manual, automatic, stop.
Through the software setting of controllers can be set to the engine controller (not choose the
power voltage input), suitable for control of pump unit.
Panel with a red light emitting diode (LED) display and alarm status.
A variety of temperature, pressure, oil level sensor can be used directly, and can custom parameters:
Temperature, pressure sensor, respectively, and temperature, pressure alarm in parallel, in providing
the digital quantity at the same time increase the level of protection.
Many successful starting condition (rotational speed sensor, oil pressure, power generation) can
choose.
Four fixed relay output( fuel oil output, starter output, to stop the output, Idle speed output).
A programmable output, can be set to public alarm output, stop failure output,preheating output
or idle speed control output function.
Allow the user to change the setting of parameters, and memory in the internal FLASH memory, will
not be lost in the system when the power is off, the controller from the front panel of the controller. All
the parameters can be adjusted, or through the USB interface by the PC machine USB power supply
controller, through monitoring software for parameter setting.
4. SPECIFICATION
project
content
Working Voltage
DC8. 0V to 35. 0V, Continuous Power Supply
Overall Consumption
standby mode: 12V0.3W 24V0.4W
working: 12V
1W 24V
1.1W
AC voltage Input
Single phase 2 Wire 15V AC - 360 V AC (ph-N)
Alternator Frequency
50/60Hz
Speed Sensor Voltage
1V --24V(effective value)
Speed Sensor Frequency
maximum 10kHz
The maximum total run time
99999.9 hours (After the decimal point is 1/10 hours
Six minutes
once changes)
Start Relay Output
1Amp DC28V B+ power supply
Fuel relay output
1Amp DC28V B+ power supply
Shutdown relay output
1Amp DC28V B+ power supply
Idle speed relay output
1Amp DC28V B+ power supply
Programmable relay output
1Amp DC28V B+ power supply
Switch input port
After B - effective
Overall Dimensions
97mm x 78mm x 44mm
Panel Cutout
78mm x 66mm