5.1 First Operation
Before loosening the cover screw fasteners 2,
the reservoir must be depressurized
(pressure-free)!
Reservoir 97105 or 97107:
Set the depressurizing valve 5 to position
(depressurize).
Automatic reservoir only:
The automatic reservoir is depressurized when the power switch on the controller 97102 or 97103 is
switched to the O (OFF) position or the digital display indicates no pressure.
In case of doubt:
Set the depressurizing valve 5 to position (depressurize).
5.1.1 Inserting the Product Bottle
Loosen the cover screw fasteners 2 and remove the cover 1.
Check that the dispensing valve is connected correctly according to the instruction manual.
Never fill the product directly into the reservoir!
The safety devices would become clogged and therefore ineffective!
Insert a full product bottle in the reservoir
Automatic reservoir only:
Check that the product bottle inserted in the bottle nesting block is pressed against the level sensor
(see Section 4.3).
Insert the product hose into the bottle and put
on the cover 1.
Uniformly tighten the cover screw fasteners 2.
Set the depressurizing valve 5 to position (pressurize).
On the controller 97102, switch the reservoir to active with the button .
On the controller 97103, switch the reservoir to active with button or .