36
Type of malfunction Possible causes Correction
No product. Product reservoir is empty.
The red LED on the automatic reservoir
is lit.
Product reservoir is not switched on.
Reservoir (product reservoir) is not active.
Product reservoir defect.
Refill the product reservoir
(Section 5.2)
On the automatic reservoir, one of the
seven yellow LED´s was previously lit.
The lower the lit LED, the lower the filled
level.
Set the depressurizing valve to
(pressurize).
Controller 97102: Press button .
Controller 97103: Press button or
.
Loctite Service.
B
A
Troubleshooting7
Replacing the Rupture Disc
When the maximum allowable air supply pressure is exceeded, the reservoir is depressurized by the
bursting of the rupture disc. he punctured rupture disc must be replaces.
Loosen the cover screw fasteners 2 and remove
the cover 1.
Remove the screws and open the housing.
Remove the rupture disc screw.
Replace the punctured rupture disc with a new
one.
Replace and tighten the rupture disc screw.
Tightening torque: maximum 20 Nm
Affix the sypplied type plate.
Close the housing. Insert and tighten the screws.
XS2/IN: Controller
XS2/OUT:Tank B
max. operating pressure
8 bar
operating temperature.
0 to +50C
volume:
3,5 Liter
Loctite (Ireland) Ltd.
M
a
d
e
in
G
e
r
m
a
n
y
X
S
2
/IN
X
S
2
/O
U
T
P in
20 Nm