Product and Function
14 www.loepfe.com
WeftMaster CUT-iT
The 4 different current flow modes
Mode Description
Off mode Output current is switched off.
Display: «POWER OFF» (switched off)
Standby mode Time in which the weaving machine is idle. Predefined current flows
through the cutting wires during this time. This achieves an optimum out-
put temperature for the machine to run.
Display: «Standby»
Boost mode Weaving machine starting phase. Predefined current flows through the
cutting wires for a limited time. This current heats the cutting wires as
quickly as possible to operating temperature.
Display: «Boost» (startup current)
Run mode Time in which the weaving machine is running. The predefined current
flows through the cutting wires during this time.
Display: «Run» (running current)
The WeftMaster CUT-iT stops the weaving machine in the following cases
n The power supply is interrupted.
n A system error is detected.
n No cutting wire is connected.
n A cutting wire is broken (defective).
n A connection cable is interrupted.
n WeftMaster CUT-iT restarts.
3.2 Scope of Delivery
The following components are included in the scope of delivery:
n 1 control unit WeftMaster CUT-iT
Optional
n Heat cutters depending on suitability:
– 1 heat cutter F Ceramic
– 1 heat cutter R Ceramic (short)
– 1 heat cutter R Ceramic (long)
– 1 heat cutter FL Ceramic
– 1 heat cutter F Steel
– 1 heat cutter F Steel with foot
n Power supply 24 V DC
n Auxiliary parts according to Spare Parts catalog