SMARTNEO - OPERATING MANUAL // PAGE 8
2.7 RESIDUAL RISKS
Residual risks are the risks that remain after all relevant safety standards have been complied with. These
have been evaluated in the form of a risk assessment. Residual risks associated with the operation of the
table system as a whole are listed here and throughout this Operating Manual. The risks associated with
the installation of other products in the system are detailed in the respective product’s Operating Manual.
See also Chapter 1.1 Other Applicable Documents on page 5. The symbols and signal words used in this
Operating Manual are listed in Chapter 2.5 Explanation of Symbols and Signal Words on page 7.
WARNING Risk of death or serious injury through electric shocks
The SMARTneo-2G is an electrical device. Basic safety precautions must be taken at
all times. Failure to observe electrical safety precautions may lead to death or serious
injury through electric shocks.
Never open the SMARTneo-2G or its components
Ensure that the SMARTneo-2G is not connected to the mains during assembly
Ensure that the SMARTneo-2G is supplied with the mains voltage specied on the
Type Plate
Do not convert or modify the SMARTneo-2G in any way
Do not place the Cable of the SMARTneo-2G on heated surfaces
Do not immerse the SMARTneo-2G or its components in liquid. Clean only with a
dry or slightly damp cloth
Check the housing and cables of the SMARTneo-2G for visible damage. Do not in-
stall or operate damaged products.
WARNING Risk of death or serious injury in explosive atmospheres
Operating the system in potentially explosive atmospheres may lead to death or serious
injury through explosions.
Read the relevant directives to determine if an atmosphere is potentially explosive
Do not operate the system in potentially explosive atmospheres
WARNING Moderate risk of serious injury through electric shocks
While cleaning or using the system, liquid intrusion may lead to serious injury through
electric shocks.
Do not allow any components to become wet during cleaning
Ensure components are placed away from areas where spillages are likely to occur
Take care not to spill liquids onto or around the system
WARNING Moderate risk of serious injury through electric shocks
Inserting incorrect cables into the SMARTneo-2G may lead to death or serious injury
through electric shocks.
Ensure only LOGICDATA-approved products are connected to the SMARTneo-2G
Do not insert incompatible cables into the SMARTneo-2G
Do not attempt to force cables into the incorrect plug ports
CAUTION Risk of minor or moderate injury through unexpected movement
Exceeding the static or dynamic load limits of the Table System may cause unexpected
operation. This may lead to minor or moderate injury.
Do not exceed load limits

Table of Contents

Other manuals for LOGICDATA SMARTneo-2G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LOGICDATA SMARTneo-2G and is the answer not in the manual?

LOGICDATA SMARTneo-2G Specifications

General IconGeneral
BrandLOGICDATA
ModelSMARTneo-2G
CategoryControl Unit
LanguageEnglish

Related product manuals