electric devices. The AC pilot light (Green) will go
off and the overload indicator light (Red) will stay
on, but the engine will not stop running.
When the overload indicator light comes on and
power generation stops, proceed as follows:
1. Turn off any connected electric devices and
stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
3. Check for blockages in the cooling air inlet
and around the control unit. If any blockages
are found, remove.
4. After checking, restart the engine.
TIP:The overload indicator light may come on for
a few seconds at first when using electric
devices that require a large starting current,
such as a compressor or a submergible
pump. However, this is not a malfunction.
AC pilot light (Green)
The AC pilot light ① comes on when the
engine starts and produces power.
DC protector
The DC protector turns to “OFF” ②
automatically when electric device being
connected to the generator is operating and
current above the rated flows. To use this
equipment again, turn on DC protector by
pressing its button to “ON” ①
① “ON”
Direct current is output.