EasyManua.ls Logo

LONCIN LC 2000i - Application Range

LONCIN LC 2000i
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Application range
When using the generator, make sure the total load is within rated output of a
generator. Otherwise, generator damage may occur
AC
Power
factor
1 0.8-0.95
0.4-0.75
(Efficiency 0.85)
LC2000i ~1,600W ~1,280W ~544W
Rated voltage 12v
Rated current8.3A
TIP
· “~”means below.
· Application wattage indicates when each device is used by itself.
· The simultaneous usage of AC and DC power is possible but total wattage
should not exceed the rated output.
EX:
Generator rated output 1,600VA
Frequency Power factor
1.0 1,600W
AC
0.8 1,280W
DC ---
100W
(12V/8.3A)
The overload indicator light comes on when total wattage exceeds the
application range. (See page 14 for more details.)