6. Turn the 3 in 1 switch to “OFF”.
7. Tighten the drain screw
8. Install the cover and tighten the screws.
9. Turn the fuel tank cap air vent knob to
“OFF” after the engine has completely
cools down.
Engine
Perform the following steps to protect the
cylinder, piston ring, etc. from corrosion.
1. Remove the spark plug, pour about one
table- spoon of SAE 10W-30 into the spark
plug hole and reinstall the spark plug.
Recoil start the engine by turning over
several times (with 3 in 1 switch knob off)
to coat the cylinder walls with oil.
2. Pull the recoil starter until you feel
compression. Then stop pulling. (This
prevents the cylinder and valves from
rusting).
3. Clean exterior of the generator.
Store the generator in a dry,
well-wentilated place, with the cover
placed over it.
TROUBLESHOOTING
Engine won’t start
1. Fuel systems
No fuel supplied to combustion chamber.
{ No fuel in tank…Supply fuel.
{ Fuel in tank….Fuel tank cap air vent knob
and fuel cock knob to “ON”.
{ Clogged fuel filter …. Clean fuel filter.
{ Clogged carburetor…. Clean carburetor
2. Engine oil system
Insufficient
{ Oil level is low…. Add engine oil.
3. Electrical systems

Questions and Answers: