② “OFF”
Direct current is not output.
Reduce the load of the connected electric device
below the specified rated output of the generator if
the DC protector turns off. If the DC protector turns
off again, stop using the device immediately and
consult a LONCIN dealer.
Engine smart control (ESC)
“ON”
When the ESC switch is turned to “ON”,
the economy control unit controls the
engine speed according to the connected
load. The results are better fuel
consumption and less noise
.
“OFF”
When the ESC switch is turned to“OFF”,
the engine runs at the rated r/min
(5000r/min)
regard-less of whether is a load connected
or not.
Tip: The ESC must be turned to“OFF”when
using electric devices that require a large
starting current, such as a compressor of a
submergible pump
Fuel tank cap
Remove the fuel tank cap by turning it
counterclockwise.