Fuel tank cap air vent knob
The fuel tank cap is provided with an air
vent knob to stop fuel flow. The air vent
knob must be turned to “ON”. This will allow
fuel to flow to the carburetor and the engine to
run. when the engine is not in use, turn the
air vent knob to “OFF” to stop fuel flow.
Ground (Earth) terminal
Ground (Earth) terminal connects the
earth line for prevention of electric shock.
When the electric device is earthed, always
the generator must be earthed.
Parallel Operation Outlets
This is the terminal for connecting special
cables for parallel running of two LC2000i.
The parallel running requires two LC2000i
and the special cables. (The rated output in
parallel running is 3.0Kva and the rated
current is 25.0 A/120V 13A /230V.)
The handing, operation procedure and the
notes on usage are described in the
PARALLEL RUNNING KIT OWNER’S
MANUAL included in the Parallel Running Kit.
Consult a LONCIN dealer for this Parallel
Running Kit.