SECTION 4. DISASSEMBLY AND SERVICE
4-1-4 Low Speed / Voltage
(SEE 4-5-4)
(SEE 4-5-4)
(SEE 4-4-4)
(MOVE TO RUNPOSITION)
(SEE 4-4-4)
(SEE 3-3)
LOW
SPEED /
VOLTAGE
FUEL SYSTEM
CARBURETOR has water
CHOKE LEVER not fully open
AIR FILTER dirty
STEPPER MOTOR faulty
MOTOR open phase, MOTOR WINDING
turn-to-turn short circuit
消声器堵塞
ALTERNATOR temperature too high
OTHER
(SEE 4-5-4)
(REMOVE EXTRA LOADS)
ELECTRICAL LOADS too high
(ADD CLEAN FRESH FUEL OF DESIGNATED
QUALITY INTO TANK)
FUEL QUALITY poor / contaminated
ALTERNATOR temperature too high
(SEE 4-5-5)
INVERTER faulty
GOVERNOR
SYSTEM