SECTION 4. DISASSEMBLY AND SERVICE
4-1-6 No AC Output Voltage
4-1-7 No DC Output Voltage
4-2 准备维修
(SEE 4-5-4)
(SEE 4-5-5)
(CHECK IT AND ADJUST)
(CHECK FOR BURN, IF SO, REPLACE IT)
NO AC
OUTPUT
VOLTAGE
ENGINE SPEED abnormal
STATOR WINDING COIL defective
OUTPUT RECEPTACLE faulty
INVERTER faulty
(PLEASE SEND IT TO THE CLIENT SERVE
CENTER)
NO DC
OUTPUT
VOLTAGE
DC WINDING short circuit or open circuit
(SEE 4-5-5)
INVERTER faulty
(REINSERT IT, SEE 4-5-5)
RECTIFIER BRIDGE CONNECTION loose
or faulty
- 16 -