SECTION 4. DISASSEMBLY AND SERVICE
engine.
2. Lower total power of all connected electrical
equipment into the range of rated output.
3. Check cooling air intake port for obstruction by
foreign matters, and whether relevant control
parts are abnormal, if so, solve the problem
immediately.
4. Restart the engine after checking.
Note: When using electric equipment with high
starting current (like compressors, submersible
pumps, etc.), the overload light might be on for
some seconds immediately after starting, but it
doesnt indicate any fault mentioned above.
Use an ohmmeter to check the light and to
confirm continuity, if resistance value is infinite,
replace the light.
AC indicator light (green)
When engine is started and has normal output, AC
indicator light turns on.
Use an ohmmeter to check the light and to
confirm continuity, if resistance value is infinite,
replace the light.
DC breaker protector
When electronic equipment connected to the
generator works and its current exceeds rated
value, the DC switch will automatically shift to
“OFF” position. Put DC switch to ON position
before operating the generator again.
Use a VOM meter to check continuity between DC
breaker protectors terminals. They should have
continuity when the protectors button is pushed
down.
Power down switch
“ON”
When power down switch is in “ON” position,
- 52 -