7. Service and Maintenance
7.1.3 Calibrating the Vaporizer
Since all vaporizers have different electrical qualities, the Tiny CX must be recalibrated
after every exchange of the vaporizer.
IMPORTANT: During the calibration process the vaporizer temperature must be at
70°F.Neverstartfoggingbeforethecalibratingprocess.Toocoldortoowarmunits
mustrstadapttotheroomtemperature(70°F).
a) Insert the battery into the machine until it clicks into place.
Please note: Do not switch on the machine by pressing the start button in the ma-
chines lid. If the LED is flashing wait until the machine switches off and the LED stop
flashing (approx. 1 minute).
b)Pressthecalibrationbutton(cal)[8]atthesideofthemachinewithasmallscrewdri-
ver or something similar.
Thecalibratingprocessnowstartsautomatically.TheyellowLED[5]ashessixtimes
with a short pause after the second and the fourth flash to confirm the calibrati-
on.
c) The calibration process is now complete.