7. Service and Maintenance
7.2 If the machine does not work perfectly
– thebatteryisdischarged(yellowchargeindicator(LED)[5]lightsuppermanently,
the pump automatically cuts off) => charge the battery
– the fluid tank or the fluid tubing is empty or the connecting spout of the fluid tubing
is not correctly plugged into the quick connector on the fluid tank
=> refill the fluid tank, check to see that the tubing plug is properly connected to
the quick connector
– the vaporizer is clogged or broken => change the vaporizer (see point 7.1)
7.2.1 There will be no fog, if…
7.2.2 Status and error display
TheyellowLED[5]…
– flashes once
Battery status display: if the LED flashes slowly, the battery is well charged, if the
LED flashes quickly the battery has to be recharged.
– flashes twice in a row
Vaporizer is broken: change the vaporizer as described in point 7.1.
Important: The new vaporizer must be calibrated!
– flashes five times in a row
Vaporizer cannot be calibrated: Try once again to calibrate the vaporizer as explained
in point 7.1. If this should not help, the vaporizer is broken and cannot be used.
– lights permanently
The battery is completely discharged: recharge the battery.