Commissioning
909.2759.9-00 - 27 -02.16
14.4 Call secondary parameters
(ControlPro)
Select the desired operating mode with button 16.
LED 13, 14 or 15 is lit.
Press button 16 for 2 sec.
The parameter code and the associated setting value
are shown in turn in the 7-segment display 19.
Select the desired secondary parameter by turning the
rotary knob 12.
Conrm the secondary parameter by pressing the
control knob 12.
The setting value ashes in the 7-segment display 19.
Set the desired value by rotating the control knob 12.
Conrm the setting by pressing the control knob 12.
Select the next secondary parameter by turning rotary
knob 12 or exit the secondary parameters by pressing
button 16.
Different secondary parameters are available depend-
ing on the selected operating mode.
Code Parameter
Standard
value
Setting
range
Mode
CEL
MMA
TIG
AEd
Arc end detection
(%)
100 0...200 x x
dAF Arc Force (%) 100 0...200 x x
Sbt
Auto-Standby
time (min)
30
Off,
5...30
x x x
StE
Hotstart (%) 125 5...200 x x
Start current (%) 50 5...200 x
Stt
Hotstart time (s) 1 0...20 x x
Start current
time (s)
0.1 0...20 x
rEd
Display version
number
- - x x x
rEL
Master version
number
- - x x x