Front panels
- 12 - 02.20909.2710.1-06
5 Common Logic Functions
component function event
fan (power unit) on power module temperature > 40°C
off power module temperature < 40°C
fan (cooling system)
waterpump
on after detection “arc established”
off after welding two minutes post cooling-time
Tab. 1: Common logic functions
6 Front panels
6.1 Front panel P-Synergic / S-Pulse / S-SpeedPulse 3.0
1
2
53 4
Fig. 4: Front panel S 3.0
6.2 Front panel functions S/P
Gas test
press the buttons “arrow up” [1] and “gas type“ (+) [2] at the same time
the gas valve is activated for 30 sec.
a countdown is shown in the display
press button “gas type“ (+) [2] again to end the test manually
Pump / fan test
press the buttons “arrow up” [1] and “material type“ (-) [4] at the same time
the cooling pump and the fans of the power unit are activated for one minute
press button “material type“ (-) [4] again to end the test manually
Reset
press the buttons “arrow up” [1] and “TT Enter” [5] at the same time
all secondary parameters are reset to their default values
if Tiptronic is active, the settings of the current job are reset to their programmed values
all adjustments of the Extras menu remain unchanged