EasyManua.ls Logo

LORCH P-Basic - Pc-Board DK-PWRUP; DK-PWRUP02

LORCH P-Basic
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pc-Boards
- 35 -02.20 909.2710.1-06
7.12 Pc-board DK-PWRUP / DK-PWRUP02
The pc-board DK-PWRUP is the charge-up control of the S3 and P3500. Depending on the type of the water
pump or the application, the DK-PWRUP or the DK-PWRUP02 is used.
cooling unit DK-PWRUP DK-PWRUP02
water pump standard “high pressure”
application standard intermediate feeder
fuses 2 x 4A / 500V (slow) 2 x 6.3A / 500V (slow)
Tab. 20: Useage pc-boards DK-PWRUP
Functions
limitation of inrush-current when charging up the capacitors on pc-board DCDR
supply for control transformer
Measuring points
designation
measuring
point
result
mains input L1 X5 ~
400V ACmains input L2 X6 ~
mains input L3 X7 ~
mains output L1 X1 ~
400V ACmains output L2 X2 ~
mains output L3 X3 ~
supply voltage control transformer X10-1
X10-2
~
~
400V AC
relay voltage X4-1 + -3
X4-2 + -4
+
-
+24V DC
Tab. 21: Measuring points PWRUP
Picture pc-board DK-PWRUP
Fig. 23: Pc-board DK-PWRUP

Related product manuals