Troubleshooting
- 61 -02.20 909.2710.1-06
9.11 Encoding power units
During the initialisation of the machine (switching on), the MAPRO pcb is detecting what power units are
connected. The identification of the power units is made by a DIP switch at the DCDR pcbs. Should the
MAPRO detect that the configuration is not valid, it will stop and displays E25 (Power module detection).
Schematic
DIP1 DIP2 setting type
OFF OFF 240A S5 / P4500
OFF ON 350A S3 / P3x00
ON OFF 300A S8 / P5500
ON ON reserved
Tab. 34: Power unit configuration