Guide for troubleshooting for PS2 pump controller
Version: V210126
Remove all additional cables which are
connected to accessories
Bend the jumper cable up or remove the
jumper cable to secure a proper contact
between the terminal clamp and the
test prods
Contact with the red measuring tip (+)
the terminal clamp 13 (Water sensor) on
the Power-board as shown in the picture
Touch with the black measuring tip
(COM) the terminal clamp 15 on the
Power-board as shown in the picture