Chapter 5 Internal Memory & I/O Signals
5-2
5.1.2 Details & Data Configuration
1) Count mode setting (CH0: 0 address, CH1: 25 address)
Setting value(Dec) Details
0 Linear count
1 Ring count
2) Pulse input mode setting (CH0: 1 address, CH1: 26 address)
Setting value(Dec) Details
0 2-phase 1-multiplication
1 2-phase 2-multiplication
2 2-phase 4-multiplication
3 CW / CCW
4 1-phase, 1-input, 1-multiplication
5 1-phase, 1-input, 2-multiplication
6 1-phase, 2-input, 1-multiplication
7 1-phase, 2-input, 2-multiplication
3) Comparison output types (CH0: 8, 9 address, CH1: 33, 34 address)
Setting value Details
0 If present value < compared reference value, OUT is On
1 If present value =< compared reference value, OUT is On
2 If present value = compared reference value, OUT is On
3 If present value >= compared reference value, OUT is On
4 If present value > compared reference value, OUT is On
5 If compared minimum value =< present value =< compared maximum value, OUT is On
6
If compared minimum value >= present value, present value >= compared maximum
value, OUT is On
Here, means 0 or 1.
4) Auxiliary mode setting (CH0: 18 address, CH1: 43 address)
Setting value(Dec) Details
0 Auxiliary mode is not used
1 Count Clear
2 Count Latch
3 Sampling Count
4 Input Frequency Measure
5 Revolution/Unit time
6 Count Disable
5) Frequency mode setting (CH0: 21 address, CH1: 46 address)
Setting value(Dec) Details
0 1 Hz unit displayed
1 10 Hz unit displayed
2 100 Hz unit displayed
3 1000 Hz unit displayed ( = 1kHz )
6) Output status setting at PLC stop (CH0, CH1 common: 50 address)
Setting value(Dec) Details
0 Output disable
1 Output kept as it is