DECLARATION OF CONFIRMITY
vi
TECHNICAL STANDARDS APPLIED
The standards applied in order to comply with the essential requirements of the Directives
73/23/EEC "Electrical material intended to be used with certain limits of voltage" and
89/336/EEC "Electromagnetic Compatibility" are the following ones:
• EN 50178:1998
“Electronic equipment for use in power installations”.
• EN 50081-2:1993
“Electromagnetic compatibility-Generic emission standard. Part 2 :
Industrial environment.”
EN 55011:1998+A1:1999
“Industrial, scientific and medical(ISM) radio-frequency equipment
Radio disturbance characteristics-Limits and methods of
measurement.
• EN 50082-2:1995
“Electromagnetic compatibility-Generic immunity standard. Part 2:
Industrial environment.”
EN 61000-4-
2:1995+A1:1998
• EN 61000-4-3:1995
• EN 61000-4-4:1995
• EN 61000-4-5:1995
• EN 61000-4-6:1996
• EN 61000-4-8:1993
• EN 61000-4-11:1994
“Electromagnetic compatibility (EMC). Part 4-2: Testing and
measurement techniques. Electrostatic discharge immunity test.”
Electromagnetic compatibility (EMC). Part 4-3: Testing and
measurement techniques. Radiated, radio-frequency,electromagnetic
field immunity test.
Electromagnetic compatibility (EMC). Part 4-4: Testing and
measurement techniques. Electrical fast transients / burst immunity
test.”
Electromagnetic compatibility (EMC). Part 4-5: Testing and
measurement techniques. Surge immunity test.”
Electromagnetic compatibility (EMC). Part 4-6: Testing and
measurement techniques. Immunity to conducted disturbances,
induced by radio-frequency fields.
Electromagnetic compatibility (EMC). Part 4-8: Testing and
measurement techniques. Power frequency magnetic field immunity
test.”
Electromagnetic compatibility (EMC). Part 4-11: Testing and
measurement techniques. Voltage dips, short interruptions and voltage
variations immunity test.”
• ENV 50140:1993
“Electromagnetic compatibility - Basic immunity standard - Radiated
radio- frequency electro magnetic field - Immunity test.”
• ENV 50141:1993
• ENV 50204:1995
“Electromagnetic compatibility. Basic immunity standard. Conducted
disturbances induced by radio-frequency fields.”
“Radio electromagnetic field from digital radio telephones.”