Registers
- 50 -
Modbus RS485 Interface
Operating Guide
Registers
Suspended Solids / Turbidity Configuration Continued
4987 Get/Set Channel 1 Curve A Point
9*
FLOAT Curve A Point 9 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5577 Channel 2
6177 Channel 3
4989 Get/Set Channel 1 Curve A Sensor
Point 9*
FLOAT Curve A Sensor Point 9
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5579 Channel 2
6179 Channel 3
4991 Get/Set Channel 1 Curve A Point
10*
FLOAT Curve A Point 10 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5581 Channel 2
6181 Channel 3
4993 Get/Set Channel 1 Curve A Sensor
Point 10*
FLOAT Curve A Sensor Point 10
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5583 Channel 2
6183 Channel 3
4995 Get/Set Channel 1 Curve B points* INT Curve B Number of
Points
*(Not Available when
Units Set to PS)
2 to 10
5585 Channel 2
6185 Channel 3
4996 Get/Set Channel 1 Curve B Point
1*
FLOAT Curve B Point 1 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5586 Channel 2
6186 Channel 3
4998 Get/Set Channel 1 Curve B Sensor
Point 1*
FLOAT Curve B Sensor Point 1
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5588 Channel 2
6188 Channel 3
5000 Get/Set Channel 1 Curve B Point
2*
FLOAT Curve B Point 2 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5590 Channel 2
6190 Channel 3
5002 Get/Set Channel 1 Curve B Sensor
Point 2*
FLOAT Curve B Sensor Point 2
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5592 Channel 2
6192 Channel 3
5004 Get/Set Channel 1 Curve B Point
3*
FLOAT Curve B Point 3 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5594 Channel 2
6194 Channel 3
5006 Get/Set Channel 1 Curve B Sensor
Point 3*
FLOAT Curve B Sensor Point 3
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5596 Channel 2
6196 Channel 3
5008 Get/Set Channel 1 Curve B Point
4*
FLOAT Curve B Point 4 Value
*(Not Available when
Units Set to PS)
Value Dependant On
Range
5598 Channel 2
6198 Channel 3
5010 Get/Set Channel 1 Curve B Sensor
Point 4*
FLOAT Curve B Sensor Point 4
Value
*(Not Available when
Units Set to PS)
0 to 16000
0 to 32000 (turbidity)
5600 Channel 2
6200 Channel 3