Coils
Modbus RS485 Interface
Operating Guide
- 85 -
Coils
Reset Custom Ranges
Auxiliary mA
Input
Reset Auxiliary mA Input Custom Curve A Channel 1 465 0 = N/A
Channel 2 480 1 = Activate
Channel 3 495
Reset Auxiliary mA Input Custom Curve B Channel 1 466
Channel 2 481
Channel 3 496
Elect Cond Reset Electrodeless Custom 1 Range Channel 1 470
Channel 2 485
Channel 3 500
Reset Electrodeless Custom 2 Range Channel 1 471
Channel 2 486
Channel 3 501
Suspended
Solids
Reset Suspended Solids Custom 1 Range Channel 1 475
Channel 2 490
Channel 3 505
Reset Suspended Solids Custom 2 Range Channel 1 476
Channel 2 491
Channel 3 506
Data logging
Unit Start/Stop SD Card Data logging 515 0 = Stop
1 = Start
Save Live Trend Data
Unit Save Live Trend Data To SD Card Trend 1 520 0 = N/A
Trend 2 521 1 = Activate
Trend 3 522
Suspended Solids / Turbidity - CIP
Suspended
Solids /
Turbidity
Turn On/Off Suspended Solids Sensor Clean In Place (CIP)
Mode
Channel 1 525 0 = Turn Off
Channel 2 526 1 = Turn On
Channel 3 527