1 Using the KEYPAD KP200
KEYPAD KP200
1-9
DE
EN
FR
Note: In the case of parameters with large value
ranges the value is entered as an exponent
(e.g. 10.00 E3 = 10,000; 25.15 E-2 = 0.2515). Use the up
key to increase the flashing character and the down key
to move to a new character.
1.6.1 Names of the subject areas
The names of the subject areas comprise a two-digit number and an
abbreviation for the range (example: _36KP = K
EYPAD). The number
36 signifies the range of parameter numbers from 360 to the next
subject area _38TX - that is, to parameter number 380.
Note: This means that parameters with number
362 or 371 are usually to be found in subject area _36KP!
Exceptions: For reasons of compatibility, the parameter number is
not always based on the subject area number, e.g. 1-MODE in sub-
ject area _36KP. However, the only exceptions are parameter num-
bers < 150 and 400 - 499.
KEYPAD Abbreviation for
Subject area
(D
RIVEMANAGER)
User level
1-MODE
_15FC First Commissioning First commissioning 2
_18IA Inputs Analog Analog inputs 2
_20OA Outputs Analog Analog outputs 3
_21ID Inputs Digital Digital inputs 3
_24OD Outputs Digital Digital outputs 3
_26CL Control Location Control location 3
_27FF Fixed Frequencies Fixed frequencies 2
_28RS Reference Structure Reference structure 3
_30OL
Output frequency
Limits
Frequency limits 2
_31MB Motor Brake Motor holding brake 3
_32MP Motor Potentiometer MOP function 3
_33MO MOtor protection Motor protection 3
_34PF Power Failure bridging Power failure bridging 3
_36KP KeyPad K
EYPAD KP200 3
_38TX TaX values Device capacity utilization 3
Table 2.2 Overview of subject areas (depending on user level)