KEYPAD KP200
1  Using the KEYPAD KP200
1-12
1.7 Control drive (CTRL menu)
Requirements:
1. The desired control mode VFC, SFC or FOR is set in parameter 
300-CFCON in subject area _15FC
2. Power stage enable ENPO = 24 V (High level) on terminal X2:8
3. Start signal not set (e.g. ISD00 = 0 V in factory setting) 
1. Select CTRL menu
2. Press the Start/Enter key 
twice to initiate reference 
input
3. The last character flashes 
and can be altered with the 
up key. Use the down key to 
move to the next character. 
The 5th character at the far 
left indicates the direction of 
rotation: 
(–) = counter-clockwise, 
( ) = clockwise
4. The last character can be 
entered as an exponent. 
Press Start/Enter to start 
the motor at the preset refe-
rence speed
5. Press Stop/Return once, the 
motor continues running and 
a new reference can be 
entered. Activate it with 
Start/Enter. 
Press the Stop/Return key 
again to stop the motor
CTRL
CTRL
CTRL
CTRL
stop
return
stop
return
stop
return
start
enter
start
enter
start
enter
0...9
CTRL
stop
return
0...9
M