EasyManua.ls Logo

Lust KEYPAD KP200 - Control Drive (CTRL Menu)

Lust KEYPAD KP200
80 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KEYPAD KP200
1 Using the KEYPAD KP200
1-12
1.7 Control drive (CTRL menu)
Requirements:
1. The desired control mode VFC, SFC or FOR is set in parameter
300-CFCON in subject area _15FC
2. Power stage enable ENPO = 24 V (High level) on terminal X2:8
3. Start signal not set (e.g. ISD00 = 0 V in factory setting)
1. Select CTRL menu
2. Press the Start/Enter key
twice to initiate reference
input
3. The last character flashes
and can be altered with the
up key. Use the down key to
move to the next character.
The 5th character at the far
left indicates the direction of
rotation:
(–) = counter-clockwise,
( ) = clockwise
4. The last character can be
entered as an exponent.
Press Start/Enter to start
the motor at the preset refe-
rence speed
5. Press Stop/Return once, the
motor continues running and
a new reference can be
entered. Activate it with
Start/Enter.
Press the Stop/Return key
again to stop the motor
CTRL
CTRL
CTRL
CTRL
stop
return
stop
return
stop
return
start
enter
start
enter
start
enter
0...9
CTRL
stop
return
0...9
M