Frequency Characteristics of A & C.
Weighting
Network A weighting :
The characteristic is simulated as "Human
Ear Listing" response. Typical, if making
the environmental sound level
measurement, always select to A
weighting.
C weighting
The characteristic is near the "FLAT"
response. Typical, it is suitable for
checking the noise of machinery (Q.C.
check) & knowing the sound pressure
level of the tested equipment.
Time Fast - t = 125 ms
weighting * "Fast" range is simulated the human ear
(Fast & Slow) response time weighting.
Slow - t = 1 s
* "Slow" range is easy to get the average
values of vibration sound level.
Data hold To freeze the measurement value.
Function selector
SPL Auto range30130dB.
DOSE Threshold Level(Thr)7090dB in 1dB steps.
Criterion Level(Crit)80848590dB.
Exchange Rate 3, 4, 5 or 6 dB
Frequency 31.5 to 8,000 Hz.
Microphone Electric condenser microphone.
type
Microphone Out size, 12.7 mm DIA. ( 1/2 inch).
size
3