Flex EX2 Receiver Select Instruction Manual
August 2018
Page 29 of 39
4.2.5 Infrared Receiver Settings
The IR programmer unit can be used to set the system serial number, channel, type
setting, function relay settings, and many others. Refer to the Flex IR Programmer
Manual or contact Magnetek field service for more details.
Presets:
All receivers in a system are set to the same serial
number and assigned channel
Receiver A - Type 01
Receiver B - Type 02
Receiver C - Type 04
Receiver D - Type 08
Bridge receiver (non-selectable) - Type 00
Bridge receiver 1 - Type 16
Bridge receiver 2 - Type 32
FUNC RLY1 - Normal
FUNC RLY2 - RS
4.2.6 Fuse Ratings
FUSE # 110 - 120VAC
220 - 240VAC 380 - 400VAC
410 - 460VAC 24VAC
42 &
48VAC
9 - 36VDC
F3 - F10 5.0A 5.0A 5.0A 5.0A 5.0A 5.0A 5.0A
F1 - F2 0.5A 0.5A 0.5A 0.5A 1.0A 1.0A 3.0A